July 2007

Repair and enhance tower base grounding

WNOG Naples FL
June 2007

Ground System Evaluation

WYHL  Meridian MS
June 2007

Rebuild ND Ground System

KZDC  San Antonio TX
March 2007

Build New 4 tower ground system

WCIN  Cincinnati OH
June 2007

Repair vandalism damage.

WMBG  Williamsburg VA
March 2007

Build New ND ground system

KCRG Cedar Rapids, IA

 

October 2006

Rebuild 3 tower ground system and install new feed and sample lines.

KRLD Dallas TX

December 2006

Rebuild 2 tower array ground system and building ground infrastructure.

WPHE Phoenixville, PA

September 2006

2 tower DA rebuild

KDWA Hastings, MN

July 2006 ND Build

WCIN Cincinnati, OH

Feb.  2006  5 twr DA Build

WNDA Deland, FL

Dec. 2005  ND Rebuild

KMOX St. Louis, Mo

Nov. 2005  ND Rebuild & other work.

 
 
 
 
 
 
 

 

 
     
     
     
 

This Page has had

 
 

Hit Counter

 
 

Visitors Since The Site was Rebuilt September '05

 
     

 

AM Ground Systems Quote Request

With some knowledge to the site in question, this form should take about 10-15 minutes to prepare and submit. Depending on the current load of the 'net, the form should arrive in our mailbox anywhere from 5 seconds to forever after you press SUBMIT. If you have not received an acknowledgement or call back from us within 24 hours, your email may be floating around in the ether somewhere or hung up in one of the many overly aggressive spam filters... Lost forever.

PLEASE call our toll free number if you have not received confirmation of receipt within 24 hours.
1-877-766-2999

OR if you would just rather speak to a real live person to discuss your project please call the number above.  This form is purely a tool to help you and I gather information about your project.

PLEASE NOTE:
Submitting this form implies absolutely NO obligation to you.
  

This form is meant to make both of our jobs easier and save time.  Please be as specific as
possible but if an answer isn't known we can work it out later.  If some aspect of your project defies written word, or would take too long to write out, please fill out what you can, submit the form and call to discuss the rest.  The answers provided on this form will be used to compile a preliminary quote for this project.

 


First:  To verify that you are indeed a real person and not a spambot... 

What is this a picture of?    

Enter your answer below and then continue with the meaningful form info.

Spelling doesn't matter.  Nor does exactly what you type.  As long as the default text is changed we will receive the form data.  Spambots search for and file forms with mostly repetitious data.  Some days we receive over 100 spambot submitted forms.

This is a very simplistic approach to form verification.

 

Picture above is a: 

Contact Information

Date                                           

Your Name                                   

Your Affiliation with Station      

Call Sign of Station                    

Frequency                                  khz

Power                                         kW

Transmitter Location                 

Your main telephone number    

Your Cell number                          

Your Email Address                    

Transmitter Latitude                     (if available)

Transmitter Longitude                   (if available)

Consulting Engineer                    (if applicable)

Consultant Telephone                (if applicable)

Desired Start Date                    

Desired Completion Date           


Site Access

AGSC will arrive with a minimum of a 1 ton 16ft long x 11ft tall box truck and (depending on project) at least one 4 wheel drive tractor.  We may also have a 20ft long trailer and other equipment.  We typically prepare quotes based on normal site access per established standards. 

For this purpose normal access is defined as: Well established hard surface, at least 7ft wide, 12ft overhead clearance, no permits or additional permission necessary, using site property, legal right-of-way or easement.

Normal access as described above

Abnormal access (Please describe below)


Site Protections

Is the site protected or regulated by any local, state or federal agency?  I.E,  DNR, EPA, DWR, Forest Service, Park Service, etc.

Site is not protected in any way by any agency.

Site is protected   **** Describe below ****

 


 

Site Basics

Please check all that apply

  New Site

  Rebuild Existing Site

  Plats or other engineering documentation is available

Transmitter WILL be on when construction is underway

  Tower(s) will be up before construction is underway

  Conditions exist that will require job to be done at night or during restricted days/hours *** Please describe below ***

  There be other work going on while ground system is being installed? (i.e., tower work, grading/excavating, road building, building construction, etc)        ** Please describe below ***

Describe (if needed)


Site Use

Please check all that apply.

  Unknown previous site use

  Parking Lot (don't laugh)

Pasture or Crop Land

Freshly Cleared Woods

Fresh Excavation to Hardpan

Fresh Excavation with Fill Dirt

Existing Clean Tower Site

Other  *** Please describe below ***


Soil Type

We typically prepare quotes based on normal site soil per established standards. 

For this purpose normal soil is defined as: Well drained, loam or light clay, no rock ledge, no loose rock larger than 8in diameter.

 

  Unknown Soil Type

Sandy

Rocky

Clay

Gravel

Hard

Really Hard

Exposed Rock (as in rock ledges or boulders)

Soft

Muddy

Standing Water

Swamp

Good for a Parking Lot

Good for a Garden

Good for an Alligator Farm

Other (Please Describe Below)


Obstructions that may be present when ground system work begins

Please check all that apply.

  Unknown Site Obstructions

  Tower Standing

Tower laying on ground

Building...   How far from tower base? ft

Buildings (Plural) *** Please provide drawing ***

Fences around tower

Other Fences in Ground Field Area

Drainage Ditches that can be crossed

Drainage Ditches that CAN'T be crossed

Ponds, streams or standing water

  Roads that can be plowed across

Roads that CAN'T be plowed across

Parking Lot

Trees

Poles (Power, Telephone, etc)

Grave Yard

Non-mobile automobiles

Trash or other Rubbish

Excavation: Open trenches for power/Telco/etc

Excavation: Open trenches to towers for coax, etc

Excavation: Dirt Piles

Underground utilities less than 36in deep (Water, gas, power, telco, etc)

All other underground pipe/wiring/coax less than 36in deep

Will need assistance in determining underground obstructions

OTHER OBSTRUCTIONS *** Please describe below ***
 


Please check ONE to describe the site topography.

Unknown Site Topography

Level to sloping

Sloping to Rolling

Rolling to Sharply dropping away from tower

Rolling to Sharply rising away from tower

Hang on to your hat Steep

Other (Please Describe Below)


Site Security During Construction

Please check all that apply.

Unknown Site Security

10

 Please rate site security concerns on a scale of 1 to 10. Where 1 is a good neighborhood where you could leave everything unlocked without fear, and 10 where everything left onsite will be gone in the morning

Unless otherwise stated:  AGSC will be responsible for it's own equipment and materials BEFORE they are installed.  Upon installation ALL materials and and their security becomes the responsibility of the client.

Full site fence with locked gate

No full site fence but gated drive

No fence or gate on driveway

Other Security Concerns or Arrangements (Please Describe Below)


Ground System Design

Check all that apply.  Standard Minimum Ground System consists of 120 radials, 1/4 wavelength at lowest frequency.  If the station is already licensed, there is a paragraph on the STATION AUTHORIZATION (License) that describes the tower and ground system.  This ground system description would be most helpful.  If you have a CP for a station, the ground system should be described in form 301.

  Unknown Ground System Design

Standard 120 Radial System

Standard 120 Radial System with Interspersed radials of length (50ft typical)

Standard 120 Radial System with ground screen ft sq

Custom Designed Ground System with radials ft long and
ft of screen or interspersed radials

  Contact Engineering Consultant for Design

Quote ground cover consisting of weed block fabric and gravel

Radials will be shortened in some directions due to property constraints or
obstructions *** Please provide site drawing ***

Please design ground system based on included information.  Include info below


The following section is for Directional Arrays ONLY:

  Unknown DA specifics

Will radials be shortened and bonded at intersection points?

OR overlapped?

If adding a tower and ONLY constructing new ground field for it, will it be necessary to locate ends of existing radials and bond them to new system?


If you have other information concerning to your project please use the space below.


This quote is needed for:

  Curiosity

  Pending CP

  Budgetary

  Project Eminent

  Project Urgent

Thanks for taking the time to complete this questionnaire. We believe that a few
minutes spent in understanding each situation can save hours of work and lots of
headaches in the future.  If you have questions please call 877-766-2999.

Sincerely,
 

Kevin C. Kidd, CSRE

AM Ground Systems Co.

 


AM Ground Systems Company
Copyright © 2006 [AM Ground Systems Company]. All rights reserved.
Revised: 09/13/07.

AM Ground Systems Co.